Intercom Video Distribution System Crestron C2N-IVDS24x24
NET
This LED illuminates when communication between the control system and the
IVDS is established (the unit is polled on the network). Illumination indicates that
the SIMPL Windows program currently loaded has a network device defined at the
same Net ID as the IVDS. The LED flashes when communication with the processor
occurs.
SETUP LED and Pushbutton
The IVDS is TSID ready. The SETUP pushbutton and its associated LED are used
for setup of the unit’s network ID during the initial configuration of a Cresnet®
system or when the device is being added/replaced. Refer to “Method B (Touch
Settable IDs)” on page 9 for detailed information.
Industry Compliance
As of the date of manufacture, the IVDS has been tested and found to comply with
specifications for CE marking and standards per EMC and Radiocommunications
Compliance Labelling (N11785).
NOTE: This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
Setup
Network Wiring
NOTE: When installing network wiring, refer to the latest revision of the wiring
diagram(s) appropriate to your specific system configuration, available from the
Downloads | Product Manuals | Wiring Diagrams section of the Crestron website
(www.crestron.com).
When calculating the wire gauge for a particular Cresnet run, the length of the run
and the power factor of each Cresnet unit to be connected must be taken into
consideration. If Cresnet units are to be daisy-chained on the run, the power factor of
each network unit to be daisy-chained must be added together to determine the
power factor of the entire chain. The length of the run in feet and the power factor of
the run should be used in the following resistance equation to calculate the value on
the right side of the equation.
Resistance Equation
R = Resistance (refer to table below).
L = Length of run (or chain) in feet.
PF = Power factor of entire run (or chain).
R <
L x PF
40,000
Where:
The required wire gauge should be chosen such that the resistance value is less than
the value calculated in the resistance equation. Refer to the table after this paragraph.
8 • Intercom Video Distribution System: C2N-IVDS24x24 Operations Guide - DOC. 6171