Thermostats Crestron CHV-TSTAT and CHV-THSTAT
SCREEN OPTIONS
Press the MODE button to access the SCREEN OPTIONS. Press VIEW to select each
option. Press the Arrow keys (▲▼) to select the value of the parameter.
NOTE: The pages in the following setup screen refer to the screens that are seen by
the user when the VIEW key is pressed in the normal operating mode.
Outdoor Page – Temperature/humidity of the outside sensor (if the optional sensor is
installed)
Global Page – Temperature/humidity selection and system status for entire house.
Allows setting of temperature/humidity throughout a multi-thermostat system from a
single location. Must be wired and programmed as part of a Cresnet system.
Remote Function Page(s) – When part of a Cresnet System, allows control of other
functions (for example: lights, alarms, etc.). Each of the two pages has two definable
buttons. The up ▲and down ▼ keys are set by indirect text for each page, refer to
“CHV-TSTAT and CHV-THSTAT Advanced Symbol” on page 24.
MODE
VIEW
T
T
CRESTRON
SETUP: SCRN OPTIONS
Disp Global Page?
Disp Outdoor Page?
Disp Rem Func Pg1?
Disp Rem Func Pg2?
Y
Y
Y
Y
Display Global Page?
Yes or No
Display Outdoor Page?
Yes or No
Display Remote Function Pages?
Yes or No
DISPLAY OPTIONS
Press the MODE button to access the DISPLAY OPTIONS. Press VIEW to select
options. Press the Arrow keys (▲▼) to select the value of the parameter.
MODE
VIEW
T
T
CRESTRON
SETUP: DISP OPTIONS
Temperature Units:
Temp display offset:
Dual Setpoint Auto:
Main Scn Lwr Obj:
F
00
Y
HM
0
F or
0
C
Offset (-6 to +6
0
) Allows the user to adjust
the displayed temperature
Main Screen Lower Object
(Under the Temperature Display)
HM - Displays Humidity
NA - No Display
OD - Outdoor temperature
Dual Setpoint Automatic
Yes or No
Allows an automatic selection of
setpoint range.
NOTE: Dual Setpoint Automatic – Selecting Yes allows the user to explicitly set the
heat and cool setpoints in auto mode. Selecting No shows one setpoint and the
thermostat automatically selects the operating systems to maintain that setpoint
temperature.
16 • Thermostats: CHV-TSTAT and CHV-THSTAT Operations and Installation Guide – DOC. 8163