Infrared Learner Crestron CNXLIR
Problem Solving
Troubleshooting
Use the following troubleshooting guide to help resolve the most common operational
problems with the CNXLIR.
CNXLIR Troubleshooting
TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION
PWR LED does not
illuminate.
12V power supply not
connected properly.
Make sure the power supply cord
is securely installed in the 12V
power port and plugged into
power outlet.
RDY LED or SGNL
LED does not
illuminate or goes out
immediately in Learn
CNXLIR is trying to
receive stray signals
(external noise such as
sunlight, etc.).
Make sure receiving window is
positioned to avoid interference
from direct sunlight and high
frequency flourescent light.
mode. Applying signal before
CNXLIR is ready.
Wait for RDY LED before
sending a signal to learn.
OVRDR LED
illuminates.
IR signal from remote is
too strong.
Increase the distance between
the IR source and CNXLIR.
Computer connection
cable is wrong type.
Make sure connection cable is a
RS-232, DB-9 "straight through"
cable with hardware handshaking
capability. Cable must include
RTS and CTS connections.
Incorrect COM port. Select correct COM port setting
using the Preferences window
(Hardware Settings tab) of the
DEAL for Windows software.
Test equipment does
not respond to IR
signals delivered by
CNXLIR.
Test signal is not being
received.
1) Reposition IR emitter and test
again.
2) Relearn and verify signal.
3) Test again.
DEAL for Windows
does not
communicate with the
CNXLIR.
6 Infrared Learner: CNXLIR Operations Guide - DOC. 8131A