Digidim 503AV / 505 RS232 AV Interface User Guide Helvar Ltd
Doc. No. 7860076 Page 14 Issue 8
8.2. Touch Screen Commands
PRES
PRESPRES
PRES
2
22
2
PRES
PRESPRES
PRES
3
33
3
DISP
DISPDI SP
DISP
ON
ONON
ON
PRES
PRESPRES
PRES
1
11
1
OHP
OHPOH P
OHP
ON
ONON
ON
LIGHTS
LIGHTSLIGHTS
LIGHTS
ON
ONON
ON
LIGHTS
LIGHTSLIGHTS
LIGHTS
OFF
OFFOFF
OFF
PROJ
PROJPROJ
PROJ
OFF
OFFOFF
OFF
SCR
SCRSCR
SCR
OFF
OFFOFF
OFF
DISP
DISPDISP
DISP
OFF
OFFOFF
OFF
OHP
OHPOH P
OHP
OFF
OFFOFF
OFF
SCENES
SCENESSCENES
SCENES TABLE
TABLETABLE
TABLEWALL
WALLWALL
WALL
WASH
WASHWASH
WASH
POWER
POWERPOWER
POWER
PROJ
PROJPROJ
PROJ
ON
ONON
ON
PRES
PRESPRES
PRES
2
22
2
S/O
S/OS/O
S/O
ON
ONON
ON
PRES
PRESPRES
PRES
3
33
3
DISP
DISPDISP
DISP
ON
ONON
ON
PRES
PRESPRES
PRES
1
11
1
OHP
OHPOHP
OHP
ON
ONON
ON
LIGHTS
LIGHTSLIGHTS
LIGHTS
ON
ONON
ON
LIGHTS
LIGHTSLIGHTS
LIGHTS
OFF
OFFOFF
OFF
PROJ
PROJPROJ
PROJ
OFF
OFFOFF
OFF
S/O
S/OS/O
S/O
OFF
OFFOFF
OFF
DISP
DISPDISP
DISP
OFF
OFFOFF
OFF
OHP
OHPOHP
OHP
OFF
OFFOFF
OFF
Select Scene 1 in Group 1 03 51
100 0000 1
= 81 hex
0001 0000
= 10 hex
0001 0001
= 11 hex
0001 0010
= 12 hex
0001 0011
= 13 hex
0000 0000
= 00 hex
100 0000 1
= 81 hex
100 0000 1
= 81 hex
100 0000 1
= 81 hex
100 0000 1
= 81 hex
100 0001 1
= 83 hex
100 0001 1
= 83 hex
0000 0010
= 02 hex
0000 0001
= 01 hex
03 51
03 51
03 51
03 51
03 51
03 51
Select Scene 2 in Group 1
Select Scene 3 in Group 1
Select Scene 4 in Group 1
Select OFF in Group 1
Group 2 lights UP
Group 2 lights DOWN
Turn address 5 ON
(Recall MAX level)
0 000100 1
= 09 hex
0000 0101
= 05 hex
0000 0000
= 00 hex
0000 0101
= 05 hex
0000 0101
= 00 hex
0000 0101
0000 01010000 0101
0000 0101
= 05 hex
= 05 hex= 05 hex
= 05 hex
0000 0000
= 00 hex
0000 0101
= 05 hex
0000 0101
= 00 hex
0000 0000
= 00 hex
0 000100 1
= 09 hex
0 000101 1
= 0B hex
0 000101 1
= 0B hex
0 000110 1
= 0D hex
0 000110 1
= 0D hex
0 000111 1
= 0F hex
0 000111 1
= 0F hex
1111111 1
= FF hex
Turn address 6 ON
(Recall MAX level)
Turn address 7 ON
(Recall MAX level)
Turn addresss 8 ON
(Recall MAX level)
Turn address 5 OFF
Turn address 6 OFF
Turn address 7 OFF
Turn address 8 OFF
Turn everything OFF
Bargraph to adjust
address 4 to a
direct level
LLLL LLLL
=00 to FE hex
0 000011 0
= 06 hex
03 51
03 51
03 51
03 51
03 51
03 51
03 51
03 51
03 51
03 51
The touch screen panel has been given the controls shown. The commands associated with these are shown below.
TOUCH SCREEN
TOUCH SCREEN TOUCH SCREEN
TOUCH SCREEN
TOUCH SCREEN
TOUCH SCREEN TOUCH SCREEN
TOUCH SCREEN
Full list of common DALI messages are contained in document:
“RS232 to DALI command list 7860077.pdf”
Example files for AMX and Crestron based on the solution above
are available from the 503 CD; File’s AMX DALI demo and Crestron DALI demo.
Group Address
Command Data
Interface instruction
Example code is in attached files
Destination of action
Group Address
Command Data
Interface instructionDestination of action
Short Address
Command Data
Interface instructionDestination of action
Short Address
Command Data
Interface instructionDestination of action
Broadcast Address
Command Data
Interface instructionDestination of action
SCR
SCRSCR
SCR
ON
ONON
ON
PROJ
PROJPROJ
PROJ
ON
ONON
ON
Figure 3: Touch Screen Controls